The Schneider SE10C320 is a 20A 10kA rated, triple pole, Type C Miniature Circuit Breaker (MCB). It is suitable for use with Loadcentre distribution boards. It is used to protect against short circuit currents and overload currents. There is a red mechanical indicator in the front of the MCB which acts as a fault trip indicator.
The Schneider SE10C340 is a 40A 10kA rated, triple pole, Type C Miniature Circuit Breaker (MCB). It is suitable for use with Loadcentre distribution boards. It is used to protect against short circuit currents and overload currents. There is a red mechanical indicator in the front of the MCB which acts as a fault trip indicator.
The Schneider SE10C350 is a 50A 10kA rated, triple pole, Type C Miniature Circuit Breaker (MCB). It is suitable for use with Loadcentre distribution boards. It is used to protect against short circuit currents and overload currents. There is a red mechanical indicator in the front of the MCB which acts as a fault trip indicator.
The Schneider SE10D306 is a 6A, triple pole MCB. It is part of the Loadcentre KQ range
The Schneider Electric SE10D310 is a triple pole Miniature Circuit Breaker (MCB) which can be used in LoadCentre KQ distribution boards. This MCB has a current rating of 10A and a type D tripping curve (magnetic setting 10-14 in). It also has a 25mm² cable capacity and is designed for highly reactive loads, such as motors, pumps and transformers.
The Schneider Electric SE10D316 is a triple pole Miniature Circuit Breaker (MCB) which can be used in LoadCentre KQ distribution boards. This MCB has a current rating of 16A and a type D tripping curve (magnetic setting 10-14 in). It also has a 25mm² cable capacity and is designed for highly reactive loads, such as motors, pumps and transformers.
The Schneider SE10D320 is a 20A, triple pole MCB. It has a D curve and is part of the Loadcentre KQ range.
The Schneider SE10D332 is a 32A 10kA rated, triple pole, Type D Miniature Circuit Breaker (MCB). It is suitable for use with Loadcentre distribution boards. It is used to protect against short circuit currents and overload currents. There is a red mechanical indicator in the front of the MCB which acts as a fault trip indicator.
The Schneider 29370 is a padlocking toggle. It is suitable for up to 3 padlocks on MCCBs up to 630A.
The LoadCentre iKQ range of single and three phase distribution boards give a flexible solution for protection, metering, switching and control.
The Schneider SE125SPP is a 125A single phasing kit for use with switch isolators in iKQ LoadCentre distribution boards.
The Schneider Electric SEE110B03 is a 10A, 1P+N RCBO from the Acti9 iC60 range. The RCBO has a ‘B’ tripping curve and 30mA earth leakage sensitivity, meaning it is suitable for applications including personnel protection.
The LoadCentre KQ range of single and three phase distribution boards give a flexible solution for protection, metering, switching and control.
The Schneider SEE106C03 is a 6A, 30mA rated, single pole, Type C RCBO, suitable for use with LoadCentre distribution boards.
The Schneider SEE110B03 is a 10A, 1P+N RCBO from the Acti9 iC60 range. The RCBO has a ‘C’ tripping curve and 30mA earth leakage sensitivity, meaning it is suitable for applications including personnel protection.
The Schneider SEE120C03 is a 20A, 1P+N RCBO from the Acti9 iC60 range. The RCBO has a ‘C’ tripping curve and 30mA earth leakage sensitivity, meaning it is suitable for applications including personnel protection.
The Schneider Electric SEE140C03 is a 40A Residual Current Circuit Breaker with Overcurrent Protection (RCBO). This plug-on device has a type C tripping curve and a 30mA earth leakage sensitivity, making it suitable for personnel protection. It also has a cable capacity of 16mm².
The Schneider Electric SEDNBP3 is an Acti 9 3P blanking plate insulation accessory with a flush enclosure mounting on the front plate.